SAMPLE COMPANY

Achievement

Papars * Corresponding Author
2023
  1. Komiya M*, Maeda N, Tsutsumi S, Ishihawa H, Mizuta R, Nishikawa Y*, Arima S, Kaneda K, Ushio K, Urabe Y. Effect of postural differences on the activation of intrinsic foot muscles during ramp-up toe flexion in young men. Gait & Posture. 2023;102:112-117. [Link]

  2. Li H*, Aratake S, Naito H, Nogawa M, Nemoto T, Togawa T, Tanaka S. Development of a Core Body Thermometer Applicable for High-Temperature Environment Based on the Zero-Heat-Flux Method. Sensors. 2023; 23: 1970. [Link]

  3. Nishikawa Y*, Sakaguchi H, Kawade S, Maeda N, Tanaka S, Hyngstrom A. Electrical Muscle Stimulation in Young Adults: Effect of Muscle Volume on Brain-Derived Neurotrophic Factor Level. European Journal of Applied Physiology. 2023; 123: 361–366. [Link]

  4. Nishikawa Y*. Reply to "Motor unit characteristics in Amyotrophic Lateral Sclerosis". Clinical Neurophysiology. in press. [Link]
2022
  1. Nishikawa Y*, Watanabe K, Chihara T, Sakamoto J, Komatsuzaki T, Kawano K, Kobayashi A, Inoue K, Maeda N, Tanaka S, Hyngstrom A. Influence of forward head posture on muscle activation pattern of the trapezius pars descendens muscle in young adults. Scientific Reports. 2022; 12: 19484. [Link]

  2. Nishikawa Y*,Holobar A, Watanabe K, Takahashi T, Ueno H, Maeda N, Maruyama H, Tanaka S, Hyngstrom A. Detecting of Motor Unit in Amyotrophic Lateral Sclerosis Using High-Density Surface Electromyography. Clinical Neurophysiology. 2022; 142: 262-272. [Link]

  3. Tashiro T, Maeda N, Tsutsumi S, Komiya M, Arima S, Mizuta R, Fukui K, Nishikawa Y, Urabe Y*. Association between sedentary behavior and depression among Japanese medical students during the COVID-19 pandemic: A cross-sectional online survey. BMC Psychiatry. 2022; 22: 348. [Link]

  4. Nishikawa Y*,Hirata K, Ito Y, Ueda K, Kimura H. Effects of assigning physical therapists exclusively to the acute-phase stroke patients ward. Journal of Physical Therapy Science. 2022; 34: 225-229. [Link]

  5. Nishikawa Y*, Watanabe K, Takahashi T, Maeda N, Maruyama H, Tanaka S, Hyngstrom A. Laterality of the activation patterns of the vastus lateralis muscle in females with Parkinson's disease during the medication state compared with healthy controls. Journal of Integrative Neuroscience. 2022; 21: 40. [Link]

  6. Komiya M, Maeda N, Nishikawa Y, Sasadai J, Morikawa M, Tashiro T, Fujishita H, Urabe Y*. Spatial distribution pattern of the electromyographic potential in the vastus medialis and lateralis muscles for three knee flexion angles during isometric knee extension. Journal of Mechanics in Medicine and Biology. 2022;22(5):2250031. [Link]
2021
  1. Nishikawa Y*, Watanabe K, Holobar A, Takahashi T, Maeda N, Maruyama H, Tanaka S, Hyngstrom A. Association between the degree of pre-synaptic pathway degeneration and motor unit firing behavior in Parkinson's disease patients. Sensors, 2021;21(19):6615. [Link]

  2. Nishikawa Y*, Watanabe K, Kawade S, Maeda N, Maruyama H. The effect of a portable electrical muscle stimulation on brain-derived neurotrophic factor in elderly people: Three case studies. Gerontology and Geriatric Meicine, 2021; 7: 2333721421104319. [Link]

  3. Maeda N*, Komiya M, Nishikawa Y, Morikawa M, Tsutsumi S, Tashito T, Fukui K, Kimura H, Urabe Y. Effect of acute stretching on the activation patterns using high-density surface electromyography of the gastrocnemius muscle during ramp-up contraction task. Sensors, 2021; 21: 4841. [Link]

  4. Nishikawa Y*, Watanabe K, Orita N, Maeda N, Kimura H, Tanaka S, Hyngstrom A. Influence of hybrid assistive limb gait training on spatial muscle activation patterns in spinal muscular atrophy type III. F1000 Research. 2021; 10: 214. [Link]

  5. Morikawa M, Maeda N, Komiya M, Hirota A, Mizuta R, Kobayashi T, Kaneda K, Nishikawa Y, Urabe Y*. Contribution of plantar fascia and intrinsic foot muscles in a single-leg drop landing and repetitive rebound jumps: An ultrasound-based study. International Journal of Environmental Research and Public Health. 2021; 18(9): 4511. [Link]

  6. Nishikawa Y*, Maeda N, Kimura H. Physical therapy for a patient with Neuromyelitis optica during the acute phase: a case report. SAGE Open Medical Case Report, 2021; 9:2050313X211011013679. [Link] [Detail]

  7. Nishikawa Y*, Takahashi T, Kawade S, Maeda N, Maruyama H, Hyngstrom A. The effect of electrical muscle stimulation on muscle mass and balance in older adults with dementia. Brain Sciences, 2021; 11(3): 339. [Link] [Detail]

  8. Maeda N*, Hirota A, Koyama M, Morikawa M, Mizuta R, Fujishita H, Nishikawa Y, Kobayashi T, Urabe Y. Intrinsic foot muscle hardness is related to dynamic postural stability after landing in healthy. Gait & Posture. 2021;86:192-198. [Link]

  9. Yoshikawa M*, Nagakawa K, Yamawaki K, Mori T, Hiraoka A, Nishikawa Y, Yoshida M, Tsuga K. Improper sitting posture while eating adversely affects maximum tongue pressuer. Journal of Dental Science. 2021;16:467-473. [Link]

  10. Nishikawa Y*, Watanabe K, Takahashi T, Maeda N, Maruyama H, Kimura H. The effect of electrical muscle stimulation on quadriceps muscle strength and activation patterns in healthy young adults. European Journal of Sport Science. 2021; 21: 1414-1422. [Link] [Detail]

  11. Nishikawa Y*, Watanabe K, Holobar A, Maeda N, Maruyama H, Tanaka S. Identification of the laterality of motor unit behavior in female patients with Parkinson’s disease using high‐density surface electromyography. European Journal of Neuroscience.2021;53:1938-1949. [Link] [Detail]

  12. Maeda N*, Urabe Y, Kotoshiba S, Komiya M, Morikawa M, Nishikawa Y, Sasadai J. Acute effects of local vibration stretching on ankle range of motion, vertical jump performance and dynamic balance after landing. Isokinetics and Exercise Science. 2021; 29: 139-145. [Link]
2020
  1. Kitano S*, Komatsuzaki T, Suzuki I, Nogawa M, Naito H, Tanaka S. Development of a Rigidity Tunable Flexible Joint Using Magneto-Rheological Compounds—Toward a Multijoint Manipulator for Laparoscopic Surgery. Frontiers in Robotics and AI. 2020;7:28. [Link]

  2. Suzuki I*, Ogawa M, Seino K, Nogawa M, Naito H, Yamakoshi K, Tanaka S. NIR spectroscopic determination of urine components in spot urine: preliminary investigation towards optical point-of-care test. Medical and Biological Engineering and Computing. 2020;58:67-74. [Link]

  3. Michiue K, Nishikawa Y*. Electrical muscle stimulation intervention in the acute-phase of neuromyelitis optica: two case reports. SAGE Open Medical Case Reports. 2020;8:1-4. [Link] [Detail]
2019
  1. Nishikawa Y*, Watanabe K, Kawade S, Takahashi T, Maruyama H, Kimura H, Hyngstrom A. The effect of a portable electrical muscle stimulation device at home on muscle strength and activation patterns in locomotive syndrome patients: A randomized control trial. Journal of Electromyography and Kinesiology. 2019; 45: 46-52. [Link]
2018
  1. Suzuki I*, Ogawa M, Seino K, Nogawa M, Naito H, Yamakoshi K, Tanaka S. Reagentless estimation of urea and creatinine concentrations using near-infrared spectroscopy for spot urine test of urea-to-creatinine ratio.Advanced Biomedical Engineering. 2018;7;72-81. [Link]

  2. Nishikawa Y*, Watanabe K, Takahashi T, Kimura H, Maruyama H. The effect of medication on vastus lateralis muscle activation patterns in Parkinson’s disease patients. Journal of Electromyography and Kinesiology. 2018; 42: 66-73. [Link]

  3. Nishikawa Y, Kokubun T, Kanemura N, Takahashi T, Matsumoto M, Maruyama H, Takayanagi K*. Effects of controlled abnormal joint movement on the molecular biological response in intra-articular tissues during the acute phase of anterior cruciate ligament injury in a rat model. BMC Musculoskeletal Disorders. 2018; 19: 175. [Link]

  4. 西川裕一*:多チャンネル表面筋電図法を用いた神経変性疾患の評価.Journal of Training Science for Exercise and Sport. 2018; 29(3): 229-235.
2017
  1. Iuchi T, Kobayashi M*, Tsuchiya S, Ohno N, Dai M, Matsumoto M, Ogai K, Sato A, Sawazaki T, Miyati T, Tanaka S, Sugama J. Objective assessment of leg edema using ultrasonography with a gel pad. PLos ONE. 2017;12(8):e0182042. [Link]

  2. Sera T*, Iwai Y, Yamazaki T, Tomita T, Yoshikawa H, Naito H, Matsumoto T, Tanaka M. Strain measurements of the tibial insert of a knee prosthesis using a knee motion simulator. Journal of Orthopaedics. 2017;14:495-500. [Link]

  3. Higashi R*, Sera T, Naito H, Matsumoto T, Tanaka M. Pulmonary kinematic analysis with non-rigid deformable registration for detecting localised emphysema. Computer Methods in Biomechanics and Biomedical Engineering: Imaging and Visualization. 2017;5;100-109. [Link]

  4. Sera T*, Higashi R, Naito H, Matsumoto T, Tanaka M. Distribution of nanoparticle depositions after a single breathing in a murine pulmonary acinus model.International Journal of Heart and Mass Transfer. 2017;108:730-739. [Link]

  5. Nishikawa Y*, Watanabe K, Takahashi T, Orita N, Kimura H, Matsumoto M, Maruyama H. Spatial electromyography distribution pattern of the vastus lateralis muscle during ramp up contractions in Parkinson’s disease patients. Journal of Electromyography and Kinesiology. 2017; 37: 125-131. [Link]

  6. Nishikawa Y*, Watanabe K, Takahashi T, Hosomi N, Orita N, Mikami Y, Maruyama H, Kimura H, Matsumoto M. Sex differences in variances of multi-channel surface electromyography distribution of the vastus lateralis muscle during isometric knee extension in young adults. European Journal of Applied Physiology. 2017; 117: 583-589. [Link]

  7. 西川裕一*,渡邊航平,上野弘貴,高橋哲也,細見直永,永野義人,折田直哉,高尾恒嗣,道上可奈,三上幸夫,丸山博文,木村浩彰,松本昌泰:パーキンソン病患者における等尺性筋収縮時の空間的な筋活動分布パターンの特徴.理学療法科学,2017; 32: 329-333.  [Link]
2016
  1. Nishikawa Y*, Hosomi N, Ueno H, Kurashige T, Ochi K, Takahashi T, Orita N, Ueda K, Maruyama H, Kimura H, Matsumoto M: Deviation in the recovery of the lower limb and respiratory muscles of patients with polymyositis: a preliminary clinical study. Journal of Physical Therapy Science. 2016; 28: 2652-2655. [Link]

  2. Nishikawa Y*, Taito S, Sarada K, Ota K, Tanabe Y, Hosomi N, Takahashi T, Maruyama H, Kimura H, Matsumoto M. A Multidisciplinary Pain, Agitation, and Delirium Management Team Can Promote Rehabilitation in the Intensive Care Unit: A case report. Progress in Rehabilitation Medicine.1; 20160010. [Link]

  3. Aoki S, Hosomi N*, Hirayama J, Nakamori M, Yoshikawa M, Nezu T, Kubo S, Nagano Y, Nagao A, Yamane N, Nishikawa Y, Takamoto M, Ueno H, Ochi K, Maruyama H, Yamamoto H, Matsumoto M. The Multidisciplinary Swallowing Team Approach Decreases Pneumonia Onset in Acute Stroke Patients. PLos One, 2016 3; 11(5): e0154608. [Link]

  4. Tozawa R, Katoh M, Aramaki H, Kawasaki T, Nishikawa Y, Kumamoto T, Fujinawa O*. Absolute and relative reliablity of lumber interspinous process ultrasound imaging measurements. Journal of Physical Therapy Science, 2016; 28(8): 2210-2213. [Link]
2015
  1. Ogaya S*, Naito H, Okita Y, Iwata A, Higuchi Y, Fuchioka S, Tanaka M. Contribution of muscle tension force to medial knee contact force at fast walking speed. Journal of Mechanics in Medicine and Biology. 2015;15:1550002. [Link]

  2. Nishikawa Y*, Aizawa J, Kanemura N, Takahashi T, Hosomi N, Maruyama H, Kimura H, Matsumoto M, Takayanagi K: Immediate effect of passive and active stretching on hamstrings flexibility: a single-blinded randomized control trial. Journal of Physical Therapy Science. 2015; 27: 3167-3170. [Link]
2014
  1. Morimoto, Tanaka S, Nogawa M, Yamakoshi K, Ogawa M. Development of an optical system for monitoring urine substances based on near-infrared spectroscopy for the use of home health care. Transactions of Japanese Society for Medical and Biological Engineering. 2014;52:O-17-O18.

  2. Okimoto K, Miyazaki M, Nogawa M, Yamakoshi K, Tanaka S. Alternative index for lactate threshold –preliminary study using a non-invasive bioimpedance cardiography.Transactions of Japanese Society for Medical and Biological Engineering. 2014;52:O-525-O526.

  3. Kakimoto M, Suzuki R, Lee J, Matsumura K, Yamakoshi T, Nogawa M, Tanaka S, Yamakoshi K. A new proposal for setting servo-control reference for accurate measurement of instantaneous arterial pressure based on the volume-compensation method. Transactions of Japanese Society for Medical and Biological Engineering.2014;52:O-520-O-521.

  4. Kiyohara D, Nagai T, Lee J, Matsumura K, Rolfe P, Yamakoshi K, Tanaka N, Yamakoshi Y, Tanaka S, Nogawa M, Yamakoshi T. A proposed highly-sensitive finger-photoplethysmograph using a sphere-shaped diffuse reflector for non-invasive measurement of blood constituents. Transactions of Japanese Society for Medical and Biological Engineering. 2014;52:O518-O519.

  5. Ogaya S*, Naito H, Iwata A, Higuchi Y, Fuchioka S, Tanaka M.Knee adduction moment and medial knee contact force during gait in older people. Gait and Pusture. 2014;40:341-345. [Link]
2013
  1. Lee J*, Matsumura K, Yamakoshi K, Rolfe P, Tanaka S, Yamakoshi T.Comparison between red, green and blue light reflection photoplethysmography for heart rate monitoring during motion. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2013;1724-1727

  2. Kwon J*, Naito H, Matsumoto T, Tanaka M. Estimation of change of bone structures after total hip replacement using bone remodeling simulation. Clinical Biomechanics. 2013;28:514-518.
2012
  1. Motoi K, Taniguchi S, Baek M, Wakugawa M, Sonoda T, Yuji T, Higashi Y, Fujimoto T, Ogawa M, Tanaka S, Yamakoshi K. Development of a wearable gait monitoring system for evaluating efficacy of walking training in rehabilitation. Sensors and Materials. 2012;24:359-373.

  2. Nishizawa Nm Hase K, Naito H. Biomechanical analysis of the foot arch function using a forward dynamic walking simulation. 2012 International Symposium on Micro-NanoMechatronics and Human Science, MHS 2012, 2012, pp. 310-312, 6492428.

  3. Naito H, Akazawa Y, Miura A, Matsumoto T, Tanaka M. Identification of individual muscle length parameters from measurements of passive joint moment around the ankle joint. journal of Biomechanical Science and Engineering. 2012;7:168-176.
2011
  1. Nogawa M*, Ogawa M, Yamakoshi T, Tanaka S, Yamakoshi K. Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2011;4344-4347.

  2. Tanaka S*, Suzuki T, Ogawa M, Motoi K, Nogawa M, Ohtake H, Watanabe G, Yamakoshi K. Evaluation of a newly designed endoscope for observing inner wall of large arteries for the use of endovascular intervention. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. 2011; 345-348.

  3. Motoi K*, Taniguchi S, Yuji T, Ogawa M, Tanaka N, Hata K, Baek M, Ueno H, Wakugawa M, Sonoda T, Fukunaga S, Higashi Y, Matsumura K, Yamakoshi T, Tanaka S, Fujimoto T, Asanoi H, Yamakoshi K. Development of a ubiquitous healthcare monitoring system combined with non-conscious and ambulatory physiological measurements and its application to medical care. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. 2011; 8211-8214.

  4. Osawa T, Matsumoto T, Naito H, Tanaka M. Mechanical-model-based evaluation of local degeneration of articular cartilage considering tissue microstructure. Transactions of Japanese Society for Medical and Biological Engineering. 2011;49:116-121.

  5. Kadokawa S, Matsumoto T, Naito H, Tanaka M. Assessment of trabecular bone architecture and intrinsic properties of cortical bone tissue in a mouse model of chronic kidney disease. Journal of Hard Tissue Biology. 2011;20:79-86.
2010
  1. Ogawa M*, Yamakoshi T, Tanaka S, Yamakoshi K. Near-infrared spectroscopy of human serum albumin and determination of its concentrations in phosphate buffer solutions. Transactions of Japanese Society for Medical and Biological Engineering. 2010;48:259-268.

  2. Tanaka S*, Hayakawa Y, Ogawa M, Yamakoshi K. Development of a near-infrared spectroscopic system for monitoring urine glucose level for the use of long-term home healthcare. Proceedings of SPIE - The International Society for Optical Engineering, 2010, 7544, 75441D.

  3. Tanaka S*, Tokugai K, Ogawa M, Motoi K, Nogawa M, Ohtake H, Watanabe G, Yamakoshi K. Development of a vascular endoscopic system for observing inner wall of large arteries for the use of endovascular intervention. Proceedings of the IEEE/EMBS Region 8 International Conference on Information Technology Applications in Biomedicine, ITAB. 2010; 5687809.

  4. Rolfe P*, Zhang Y, Sun J, Scopesi F, Serra G, Yamakoshi K, Tanaka S, Yamakoshi T, Yamakoshi Y, Ogawa M. Invasive and non-invasive measurement in medicine and biology: Calibration issues. Proceedings of SPIE - The International Society for Optical Engineering. 2010; 754454.

  5. Motoi K*, Ogawa M, Ueno H, Fukunaga S, Yuji T, Higashi Y, Tanaka S, Fujimoto T, Asanoi H, Yamakoshi K. Development and clinical evaluation of a home healthcare system measuring in toilet, bathtub and bed without attachment of any biological sensors. Proceedings of the IEEE/EMBS Region 8 International Conference on Information Technology Applications in Biomedicine, ITAB. 2010;5687774.

  6. Kwon J, Naito H, Matsumoto T, Tanaka M. Computational study on trabecular bone remodeling in human femur under reduced weight-bearing conditions. Journal of Biomechanical Science and Engineering. 2010;5:552-564.

  7. Kwon J, Naito H, Matsumoto T, Tanaka M. Simulation model of trabecular bone remodeling considering effects of osteocyte apoptosis and targeted remodeling. Journal of Biomechanical Science and Engineering. 2010;5:539-551.

  8. Kobayashi T, Leung A*, Akazawa Y, Naito H, Tanaka M, Hutchins SW. Design of an automated device to measure sagittal plane stiffness of an articulated ankle-foot orthosis. Prosthetics and Orthotics International. 2010;34:439-448.

  9. Mori H, Horiuchi S, Nishimura S, Nikawa H, Murayama T, Ueda K, Ogawa D, Kuroda S, Kawano F, Naito H, Tanaka M, Koolsta JH, Tanaka E. Three-dimensional finite element analysis of cartilaginous tissues in human temporomandibular joint during prolonged clenching. Archives of Oral Biology. 2010;55:879-886.
Books
健康・福祉工学ガイドブック 工学調査会 2001/7 田中志信
Medical Diagnostic Techniques and Procedures. Narosa Publishing House 2000/1 Yamakoshi K, Nakagawara M, Tanaka S.
筋緊張に挑む (臨床思考を踏まえる理学療法プラクティス)  文光堂 2015/06 皿田和宏、西川裕一
Presentations
2022
  1. 田中敦也西川裕一内藤尚,野川雅道,戸川達男,田中志信.汗の気化熱を利用した赤外線センサ式発汗計の開発研究.第61回日本生体医工学会.2022年6月30日.新潟市

  2. 新竹瞬陸晗子西川裕一,野川雅道,内藤尚,根本鉄,戸川達男,田中志信.暑熱環境下での使用を想定した熱流補償型深部体温計の改良.第61回日本生体医工学会.2022年6月30日.新潟市

  3. 佐内佳太,鈴木郁斗,野川雅道,内藤尚西川裕一,畑中由佳,五十嵐朗,小川充洋,山越憲一,田中志信.近赤外LEDを用いた透析液排液成分のモニタリングに関する基礎的検討.第61回日本生体医工学会大会.2022年6月30日.新潟市

  4. 佐内佳太,鈴木郁斗,内藤尚西川裕一田中志信.近赤外LEDを用いた透析液排液モニタシステムの開発.日本設計工学会2022年度春季大会研究発表講演会.2022年5月21,22日.オンライン

  5. 沼屋海輝定岡徹真内藤尚西川裕一田中志信.運動学的解析を用いた多リンク構造膝継手の評価,第50回学生員卒業研究発表講演会,2021年3月5日,オンライン

  6. 沼屋海輝定岡徹真内藤尚西川裕一田中志信.運動解析シミュレーションに基づく義足膝継手の機械的機能評価,2022年合同講演会,2022年3月4日~5日,オンライン
2021
  1. 大塚極内藤尚西川裕一田中志信.義足ソケットー断端間の接触解析による適合状態の推定.令和3年度日本生体医工学会北陸支部大会.2021年12月11日,金沢市

  2. 田中敦也西川裕一内藤尚,野川雅道,戸川達男,田中志信.汗の気化熱を利用した赤外センサ式発汗計測法の基礎検討.令和3年度日本生体医工学会北陸支部大会.2021年12月11日,金沢市

  3. 酒井樹坂口寛幸内藤尚田中志信西川裕一.多点表面筋電図法によるパーキンソン病の第一背側骨間筋における運動単位活動異常の同定.令和3年度日本生体医工学会北陸支部大会.2021年12月11日,金沢市

  4. 藤村教輔嶋田慧斗西川裕一内藤尚田中志信.姿勢変化時における循環機能評価の検討.生体医工学シンポジウム2021.2021年9月17日,オンライン

  5. 玉野敬五岩岸雄士,小松崎俊彦,田村昌也,松本勲,内藤尚西川裕一田中志信.磁気粘弾性ゲルを用いた腹腔内手術支援用多関節マニピュレータの開発.生体医工学シンポジウム2021.2021年9月17日,オンライン

  6. 西川裕一.高密度表面筋電図法を用いたパーキンソン病患者の疾患特異的な運動単位発火動態の同定.計測自動学会ライフエンジニアリング部門シンポジウム2021.2021年9月5日.オンライン

  7. Lu H, Aratake S , Nogawa M, Naito, H, Nishikaw Y, Nemoto T, Togawa T, Tanaka S. Improvement of Zero-Heat_Flux Type Deep Body Thermometer for Use in Hot Environments. EMBC2021, Oct 31-Nov. 4, Virtual Conference.

  8. 西川裕一.多点表面筋電図法による運動単位の可視化・数値化とその臨床応用.第10回TSC Night Webinar.2021年7月27日,オンライン

  9. 佐内佳太,鈴木郁人,野川雅道,内藤尚西川裕一畑中由佳,五十嵐朗,小川充洋,山越憲一,田中志信.透析排液成分の工学的モニタリングに関する基礎的検討.第60回日本生体医工学会大会.2021年6月17日,オンライン

  10. Lu H, Aratake S , Nogawa M, Naito, H, Nishikaw Y, Nemoto T, Togawa T, Tanaka S. A wearable non-invasive core temperature monitor based on the zero-heat-flux method.第60回日本生体医工学会大会.2021年6月15日,オンライン

  11. 若崎聡藤村教輔,野川雅道,五十嵐朗,川野健二,川越隆,西川裕一内藤尚田中志信.車室空間における着座姿勢の違いが身体活性に及ぼす影響の検討.第60回日本生体医工学会大会.2021年6月15日,オンライン

  12. 西川裕一, 高橋哲也, 丸山博文, Allison Hyngstrom. パーキンソン病の内服治療による筋活動変化を定量的に評価する試み.カテコールアミンと神経疾患研究会2021.2021年4月3日,オンライン
2020
  1. Lu H, Nogawa M, Naito H, Nemoto T, Togawa T, Tanaka S. A wearable continuous core temperature thermometer based on Zero-Heat-Flux method, EMBC 2020, July 20-24, 2020, Montréal, Canada

  2. Lu H, Nogawa M, Naito H, Nemoto T, Togawa T, Tanaka S. A wearable continuous core temperature measurement system based on Zero Heat Flux method, 第59回日本生体医工学会大会,2020年5月26日, Virtual Conference

  3. 玉野敬五, 小松崎俊彦, 田村昌也,松本勲,内藤尚田中志信.磁気粘弾性ゲルを用いた体腔鏡手術用多関節マニピュレータの開発, 第59回日本生体医工学会大会,2020年5月26日, オンライン

  4. 西川裕一,高橋哲也,丸山博文,Allison Hyngstrom.電気生理学的手法を用いたパーキンソン病患における運動症状を定量的に評価する試み.第61回日本神経学会学術大会.2020年

  5. Nishikawa Y, Takahashi T, Maruyama H, Kimura H. Quantitative assessment of abnormal muscle tone in Parkinson's disease patients using multi-channel surface electromyography. International Society of Electromyography and Kinesiology 2020

  6. Nishikawa Y. Clinical application of EMS for Elderly people. Internatinal Society of Electrophysiology and Kinesiology 2020

  7. 西川裕一. 筋強剛に対する薬効の定量的評価の試み.第5回中四国パーキンソン病薬物治療研究会.2020年
2019
  1. Nishikawa Y, Michiue K, Kimura H, Hyngstrom A. Disease specific motor unit behavior in Parkinson’s disease patients identified by high-density surface electromyography. 13th International Society of Physical and Rehabilitation Medicine World Congress. 2019.

  2. Nishikawa Y, Watanabe K, Takahashi T, Kawade S, Kimura H, Maruyama H, Hyngstrom A. The effect of electrical muscle stimulation on muscle strength and activation pattern in locomotive syndrome subjects: randomized control trial. World Confederation for Physical Therapy. 2019.

  3. 西川裕一. 多チャンネル表面筋電図法を用いた神経変性疾患特異的な筋活動の評価およびリハビリテーションの効果判定としての臨床応用.第19回日本電気生理運動学会大会.2019年
2018
  1. 鈴木 郁斗, 清野 公宏, 野川 雅道, 内藤 尚, 五十嵐 朗, 小川 充洋, 山越 憲一, 高田 重男. 近赤外分光法を用いた光学式尿成分分析システムの開発 -総当たり解析による至適波長と組み合わせの選定-. 生体医工学 2018年

  2. 内藤 尚, 谷本 龍馬, 野川 雅道, 田中 志信. 閉リンク機構を持つ義足膝継手を用いた大腿義足の運動解析. バイオエンジニアリング講演会 2018年
2017
  1. 内藤 尚, 大崎 謙悟. 運動シミュレーションを用いた閉リンク構造をもつ義足膝継手の評価手法の検討. バイオエンジニアリング講演会 2017年

  2. 関根 広大, 内藤 尚, 野川 雅道, 田中 志信. 9軸センサを利用した身体姿勢推定アルゴリズムの精度検証. シンポジウム: スポーツ・アンド・ヒューマン・ダイナミクス講演論文集 2017年

  3. 南 蒼一郎, 田中 亜実, 内藤 尚, 野川 雅道, 田中 志信. 運動時の心機能変化メカニズム解明を目指した運動器系・循環系統合モデルの構築:-冠循環のモデル化と心拍動時の循環シミュレーション-.バイオフロンティア講演会 2017年

  4. 林 恭平, 内藤 尚, 野川 雅道, 田中 志信. ヒト足部の立位荷重/抜重時の詳細骨格構造の挙動解析. バイオフロンティア講演会 2017年

  5. 清野 公宏, 鈴木 郁斗, 野川 雅道, 五十嵐 朗, 内藤 尚, 小川 充洋, 山越 憲一, 高田 重男, 田中 志信. 近赤外分光法を用いた光学式尿成分分析システムの開発-LED光源を想定した濃度予測精度の推定-. 生体医工学 2017年

  6. 佐々木 宏時, 小松崎 俊彦, 田村 昌也, 松本 勲, 野川 雅道, 内藤 尚, 田中 志信. 磁気粘弾性エラストマを用いた体腔鏡手術用多関節マニピュレータの開発. 生体医工学 2017年

  7. 坂下 凪浩, 田中 志信, 内藤 尚, 野川 雅道. 容積振動型外耳道内血圧計測システムの開発. 生体医工学 2017年
2016
  1. 鈴木 郁斗, 野川 雅道, 内藤 尚, 小川 充洋, 高田 重男, 山越 憲一, 田中 志信. 在宅健康管理のための光学式尿成分計測システムの試作 -LEDシステム移行を考慮した使用波長数削減の検討- 生体医工学 2016年

  2. 市村 祥, 宮地 駿, 中嶋 泰之, 野川 雅道, 内藤 尚, 山越 憲一, 染矢 富士子, 田中 志信. 心拍出量計測による無侵襲簡易体力評価に関する基礎的検討. 生体医工学 2016年

  3. 岡崎 大輔, 坂下 凪浩, 野川 雅道, 内藤 尚, 山越 憲一, 田中 志信.外耳道を検出部位とした容積振動型血圧法の検討.生体医工学2016年

  4. 長井 周平, 糸見 駿, 佐々木 宏時, 小松崎 俊彦, 田村 昌也, 松本 勲, 野川 雅道, 内藤 尚, 田中 志信. 磁性粒子複合エラストマーを用いた体腔鏡下手術支援用多関節マニピュレータの開発.生体医工学 2016年

  5. 熊橋 智史, 野川 雅道, 内藤 尚, 田中 志信. 組織酸素代謝モニタリングに向けた非侵襲血中飽和度計測法の開発. 生体医工学 2016年

  6. 永濱 敏樹, 内藤 尚, 大野 直樹, 宮地 利明, 田中 正夫. M907 立脚期における足関節モーメント発生機序の数値シミュレーションによる考察(GS2 バイオエンジニアリング(2),修士研究発表セッション).関西支部講演会講演論文集 2016年

  7. 長濱 敏樹, 内藤 尚, 大野 直樹, 宮地 利明, 田中 正夫. 1F13 立脚期における後足部の運動が足関節モーメントに与える影響に関する計算解析. バイオエンジニアリング講演会 2016年
2015
  1. 宮地 駿, 沖本 康平, 市村 祥, 野川 雅道, 内藤 尚, 山越 憲一, 染谷 富士子, 田中 志信.無侵襲的に簡易に計測可能で,かつ乳酸性閾値の代替と成り得る体力指標に関する基礎的検討.生体医工学 2015年

  2. 鈴木 郁斗, 森本 尚央, 野川 雅道, 内藤 尚, 小川 充洋, 山越 憲一, 高田 重男, 田中 志信.在宅健康管理のための光学式尿成分計測システムの開発—高尿糖サンプルを用いた濃度予測精度の検討— 生体医工学 2015年

  3. 糸見 駿, 長井 周平, 小松崎 俊彦, 田村 昌也, 松本 勲, 野川 雅道, 内藤 尚, 田中 志信. 体腔鏡下手術支援用多関節マニピュレータの開発—関節剛性制御用磁気粘弾性エラストマの試作と特性評価— 生体医工学 2015年

  4. 八十山 輝彦, 内藤 尚, 松本 健志, 田中 正夫. M1206 三次元歩行シミュレーションを用いた義足膝継手の設計支援ツールの作成(GS2,15 ロボティクス・メカトロニクス(2),修士研究発表セッション).関西支部講演会講演論文集 2015年

  5. 西川裕一 ,細見直永,青木志郎,植田一幸,伊藤義広,丸山博文,木村浩彰,松本昌泰. 急性期脳卒中症例に対する早期からの理学療法効果.第40回日本脳卒中学会総会.2015年

  6. 西川裕一 ,高橋哲也,青木志郎,越智一秀,細見直永,木村浩彰,丸山博文,松本昌泰:重度半側空間無視に対して半球間抑制に基づく介入が著効した一例.第33回日本神経治療学会.2015年

  7. 西川裕一 ,折田直哉,筆保健一,木村浩彰. 骨格筋電気刺激がパーキンソン病患者の神経筋機能に及ぼす影響:低周波刺激により持久性の改善と運動単位動員動態に変化を認めた一例.第2回日本骨格筋電気刺激研究会学術総会.2015年
Grant
科研費 KAKENHI
  • 股関節機能を失った下肢高位切断者の活動範囲を拡大する高機能動力義足の開発.
     基盤研究(B) 2021/4/1-2026/3/31:内藤尚

  • 筋強剛の定量的評価手法の確立と新規診断マーカーとしての応用.
     若手研究 2020/4/1-2022/3/31:西川裕一

  • 汗の蒸発潜熱を利用した新規発刊計測原理の創出とウェアラブル化の試み.
     挑戦的研究(萌芽) 2019/6/28-2022/3/31:田中志信

  • 近赤外多波長LEDを用いた試薬レス透析液廃液多成分連続モニタシステムの開発.
     基盤研究(B) 2018/4/-2022/3/31:田中志信
  • Completed
  • パーキンソン病の疾患特異的な筋活動に着目した新規評価ツールの確立とその臨床応用.
     若手研究(B) 2017/4/1-2020/3/31:西川裕一

  • 温度標準を内蔵した自動較正式電子体温計の開発.
     挑戦的研究(萌芽) 2017/6/30-2019/3/31:田中志信

  • 計算機シミュレーションを援用した義足適合・設計技術確立のための基礎的研究.
     基盤研究(B) 2015/4/1-2020/3/31:内藤尚

  • 近赤外領域の陰性吸光度を利用した試薬レス在宅尿成分分析システムの開発.
     基盤研究(B) 2014/4/1-2019/3/31:田中志信

  • 無侵襲的に簡易的に計測可能で,かつ嫌気的代謝閾値の代替となり得る体力指標創出の試み.
     挑戦的萌芽研究 2012/4/1-2014/3/31:田中志信

  • 足関節受動抵抗の発生器所解明とその運動中の値の推定手法の開発.
     挑戦的萌芽研究 2011-2013:内藤尚

  • 健康寿命延伸のための新規健康指標創出に関する研究.
     挑戦的萌芽研究 2010-2011:田中志信

  • 義足使用者の運動状態・運動意図推定手法の確立とそれを応用した高機能股義足の開発.
     若手研究(A) 2010-2013:内藤尚

  • 在宅ヘルスケアのための便器内蔵型光学式尿成分自動計測システムの開発.
     基盤研究(B) 2008 – 2011:田中志信

  • 近赤外分光法による局所組織酸素代謝量計測法の開発.
     基盤研究(C) 2008 - 2011:田中志信

  • 姿勢及び循環生理情報の在宅収集装置を用いた高齢者の生活リズム解.
     基盤研究(C) 1997 - 1998:田中志信

  • 水晶振動子マイクロバランスを用いた体外循環用高選択性ケミカルセンサシステムの開発.
     奨励研究(A) 1994:田中志信

  • 水晶発振子を用いた医用高分子材料の生体適合性評価システムの開発.
     奨励研究(A) 1993 - 1994:田中志信